Ini file for dunord driver

Basic dunord.ini file
If you do not have a dunord.ini file, here is a basic one. Edit it to adjust trace parameters. Note that with the 32 bit drivers, Com port, DMA and IRQ are not read from dunord.ini but from the registry.
dunord.ini (198) last rev.: 00/10/26

I-2000 and I-250x boards have switches on board.

Here are tables that will let you figure out the proper switch settings for diferent IO addresses.

I-2000 Switch setting Table

The interface uses four consecutive I/O addresses (3xC to 3xF). The switch block located on the board allows you to change the middle digit of the address range (the x in 3xC). Sixteen (16) different I/O address ranges can be used. Some of those, however, might conflict with other devices on your computer (i.e. COM1 uses 3F8 to 3FF). The following table indicates address range that are normally free on many systems, and the ones that are known to be in conflict. It also shows pictures of switch settings for most common configurations.

SWITCH SETTINGS

Address range

Switches

Comments

 

 

1

2

3

4

 

 

30C-30F (default)

ON

ON

ON

ON

Possible
Net Conflict

31C-31F

ON

ON

ON

OFF

Possible
Net Conflict

32C-32F

ON

ON

OFF

ON

 

33C-33F

ON

ON

OFF

OFF

 

34C-34F

ON

OFF

ON

ON

 

35C-35F

ON

OFF

ON

OFF

 

 

36C-36F

ON

OFF

OFF

ON

Good
choice

37C-37F

ON

OFF

ON

OFF

 

 

38C-38F

ON

OFF

OFF

OFF

Conflict
with COM

 

39C-39F

OFF

ON

ON

OFF

Good
choice

3AC-3AF

OFF

ON

OFF

ON

 

3BC-3BF

OFF

ON

OFF

OFF

 

3CC-3CF

OFF

OFF

ON

ON

 

3DC-3DF

OFF

OFF

ON

OFF

 

3EC-3EF

OFF

OFF

OFF

ON

 

3FC-3FF

OFF

OFF

OFF

OFF

Conflict
with COM

The ON position is indicated on the switch block


I-250x (Panasonic) Switch setting Table

Note that this board is not supported with the 32 bit drivers
The information is provided here for users of the 16 bit drivers that may have lost their manual.

For I250x, 8 contiguous IO addresses are used. xx0 to xx7.
Usually, one gives the first address in dunord.ini, like 300.

SWITCH SETTINGS

Address range

Switches

Comments

 

4

3

2

1

 

300 to 307(default)

-

ON

ON

ON

Possible Net Conflict

320 to 327

-

ON

ON

OFF

Possible Net Conflict

340 to 347

-

ON

OFF

ON

 

360 to 367

-

ON

OFF

OFF

Good choice

370 to 377

-

OFF

ON

ON

 

390 to 397

-

OFF

ON

OFF

Good choice

170 to 177

-

OFF

OFF

ON

 

270 to 277

-

OFF

OFF

OFF

 



Last modified: October 26, 2000 / einie
© COPYRIGHT, 1999-2000 Dunord Technologies inc.